1.800.833.7958
► Español
► 中文
PIDs are the most frequently used on-site detection instruments for volatiles at the parts-per-million (ppm) level. Since many environmental sites are of concern due to volatiles – from petroleum products or chemical usage – the PID is a necessity for providing instrumentation that will work effectively on-site. PIDs are most commonly used for the detection of volatile organic compounds (VOCs).
Geotech offers a wide variety of PIDs from leading manufacturers.
Honeywell MiniRAE 3000+ and
|
MiniRAE 3000+ | ppbRAE 3000+ |
The MiniRAE 3000+ and ppbRAE 3000+ are the most advanced handheld volatile organic compound (VOC) monitors on the market. Their photoionization detector's (PID) extended range of 0 to 15,000 ppm (1 ppb to 10,000 ppm – ppbRAE 3000+) make them ideal instruments for industrial hygiene, leak detection and HazMat.
Call 1.800.833.7958
MiniRAE 3000+ & ppbRAE 3000+ Specifications
Honeywell PID User's Guide
An advanced and accurate handheld VOC detector, designed with patented Fence Electrode Technology for unparalleled performance. Boasting an impressive measurement range from 1 ppb to 20,000 ppm and a lightning-quick response time of just two seconds, it offers superior speed without sacrificing accuracy or resistance against humidity & contamination.
Call 1.800.833.7958
FALCO Diffused Model and Pumped Model |
FALCO is the latest generation of fixed photoionization detectors (PID) that continuously detect a wide range of volatile organic compounds (VOCs). Unique to FALCO is its revolutionary Typhoon Technology safeguarding the sensor from condensing moisture for added reliability in severe weather conditions!
Call 1.800.833.7958
Ion Science FALCO Specifications
Falco Pumped V1.2 Manual
Falco Diffusion V1.3 Manual
The MiniRAE Lite+ is the most reliable handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for applications ranging from environmental to construction.
Call 1.800.833.7958
Honeywell MiniRAE Lite+ Specifications
Honeywell PID User's Guide
The Tiger XTL is perfect for those situations where safety and convenience are a must. Thanks to its thermo elastomer outer molding, the Tiger XTL is intrinsically safe and can be easily operated with just one hand - even when wearing heavy gloves. The large backlit display allows for clear viewing regardless of the light conditions and an integrated torch helps to direct the instrument's probe when light is scarce.
Call 1.800.833.7958
Tiger XTL Specifications
Tiger XTL Operator's Manual
The Titan is the first fixed, continuous, real-time benzene specific monitor on the market. Designed to specifically detect benzene ranging dynamically from 0.1 ppm to 20 ppm in petrochemical environments, providing the ultimate safety monitor for plant and workforce.
Call 1.800.833.7958
Ion Science Titan Specifications
Ion Science Titan Instrument User Manual
The UltraRAE 3000+ is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector's (PID) extended range of 0.01 to 10,000 ppm in VOC mode and 10 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.
Call 1.800.833.7958
Honeywell UltraRAE 3000+ Specifications
Honeywell PID User's Guide
An advanced and accurate handheld Benzene gas detector, designed with patented Fence Electrode Technology for unparalleled performance. Boasting an impressive measurement range from 0.01 ppm to 20,000 ppm and a lightning-quick response time of just two seconds. The Tiger XTS offers superior speed without sacrificing accuracy or resistance against humidity & contamination.
Call 1.800.833.7958
TVOC 2 is a fixed continuous monitor for the detection and measurement of total volatile organic compounds (VOCs), which can be dangerous from both a poisoning and explosive perspective. Total VOCs are detected using PID (Photoionisation detection) technology.
Call 1.800.833.7958
Ion Science TVOC 2 Specifications
Ion Science TVOC 2 Instrument User Manual
The ToxiRAE Pro PID is the world's smallest wireless volatile organic compounds (VOC) monitor. The ToxiRAE Pro PID takes worker protection to the next level by providing safety professionals wireless access to real-time instrument readings and alarm status from any location for better visibility and faster response. Featuring RAE Systems' next-generation PID sensor, the ToxiRAE Pro PID can promptly detect and accurately monitor over 300 VOCs. With an onboard library of 190 correction factors, the ToxiRAE Pro PID can be programmed to automatically read in concentrations of the specified compound.
Call 1.800.833.7958
RAE ToxiRAE Pro PID Specifications
RAE ToxiRAE Pro PID User's Guide
RAE ToxiRAE Pro PID QuickStart Guide
The Ion Science Cub is the world's smallest, lightest personal PID monitor for the accurate detection of volatile organic and total aromatic compounds. Cub gives an indication of harmful gases including benzene before they reach levels which are harmful.
Cub is available in three distinct variants; ppm, ppb and TAC mode. Choose a ppb or ppm instrument with 10.6 eV lamp for accurately detecting a wide range of VOCs dependent on your sensitivity requirements. CubTAC with 10.0 eV lamp gives accurate detection of total aromatic compounds (TACs) down to ppb levels, and Cub 11.7 offers the widest VOC detection range of any personal VOC detector.
Call 1.800.833.7958
Ion Science Cub Specifications
Ion Science Cub Instrument User Manual
VOC Pro Series Gas Detectors are fixed photoionization detectors used to monitor ambient VOC gas concentrations real-time. The instruments feature an onboard LCD display, three button programming interface, and multiple communication outputs for external communication or telemetry devices. The AirLink VOC Pro model includes closed network Wi-Fi communications for onsite data management and reporting.
Call 1.800.833.7958
RKI VOC Pro & AirLink VOC Pro Specifications
RKI VOC Pro Operator's Manual
RKI AirLink VOC Pro Operator's Manual
The Ion Science Tiger is the most advanced handheld photoionization detector (PID) with the widest measurement range on the market for volatile organic compounds (VOCs).
The unique six pin miniPID detector cell with anti-contamination design dramatically extends run time in the field. Low cost filters and lamps can be easily changed in seconds, minimizing instrument downtime, and the Tiger boasts the lowest operating costs on the market.
Call 1.800.833.7958
Ion Science Tiger Specifications
Ion Science Tiger Instrument User Manual
The Tiger Select gives fast, benzene specific, or Total Aromatic Compound (TAC) detection providing accurate, reliable data.
Call 1.800.833.7958
Ion Science Tiger Select Specifications
Tiger Select Instrument User Manual
This variant of the hugely popular Tiger VOC detector is low on cost but high on performance. Its revolutionary, patented PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run time. Combined with 24 hour battery life, these features maximize field time by minimizing erroneous readings in high humidity and drift in harsh environments.
Call 1.800.833.7958
Ion Science TigerLT Specifications
Ion Science TigerLT Instrument User Manual