1.800.833.7958
► Español
► 中文
The AR4 is designed to pump floating hydrocarbons, leachate, and condensate in total fluids applications. The AR4 is operated automatically, and needs no controller. Everything needed to operate the system is built into the pump. The design withstands the harshest and most corrosive environments such as landfills or mines.
SHORT/LOW ACTIVATION |
LONG | EXTENDED | |
Outside Diameter: | 3.5" (8.9 cm) | ||
Lengths Up To: | 48" (122 cm) | 60" (152 cm) | 72" (183 cm) |
Weight: | 13.5 lbs. (6 kg) | 15.6 lbs. (7 kg) | 17.7 lbs. (8 kg) |
Minimum Activation Level: Bottom Fill*** Top Fill*** |
35" (89 cm)/17" (43 cm) 42.5" (108 cm) |
47" (119 cm) 54.5" (138.43 cm) |
59" (150 cm) 66.5" (169 cm) |
Operating Pressure Range: | 10-120 psi (0.7-8.5 kg/cm2) | ||
Maximum Operating Temp: | 220°F (104°C) | ||
Fluid Volume/Cycle*: | .7 gal. (2.6 liter) | 1.0 gal. (3.8 liter) | 1.5 gal. (5.6 liter) |
Maximum Flow Rate**: | 8.5 gpm (32 lpm) | ||
Standard Fittings: Fluid Discharge Air Supply Air Exhaust |
SS Barb ¾" x ¾" MPT ⅜" x ⅜" MPT ½" x ⅜" MPT |
||
Materials of Construction: | Includes: SS316, FRP, FPM, PVDF, HDPE, PTFE, Viton® | ||
*Specific gravity and viscosities will alter specifications. **Flow rates will vary with site conditions. ***Activation levels shown above reflect activation levels for pumps with a bottom or top and bottom inlets. To determine the activation level for a flat bottom intake, subtract 5" (12.7 cm) from the minimum activation level measurement above. |
AR4 Short, Bottom Inlet 10' (3m) Submergence, ¾" (19mm) ID Hose |
AR4 Long, Bottom Inlet 10' (3m) Submergence, ¾" (19mm) ID Hose |
AR4 Extended, Bottom Inlet 10' (3m) Submergence, ¾" (19mm) ID Hose |
The Pneumatic Cycle Counter is mounted inline after the filter and allows you to total the volumes pumped and determine service and maintenance schedules.
Cycle Counter Specifications: | ||||
Model | GEOPC350 | |||
Material | 464 Naval Brass | |||
Size | 5" L x 2" W | |||
Thread Type | ¼" FPT | |||
Pressure Range | 40-275 psi | |||
No. of Counts Before Rollover | 999,999 |
|||
Air Supply Tubing Sizes: | ⅜" ID | ½" ID | ||
Minimum Distance To Pump | 15' | 15' | ||
Max. Distance From Pump | 350' | 300' |
Tubing |
|||
Nylon 12: | |||
Air Supply | ⅜" ID x ½" OD | ||
Exhaust | ½" ID x ⅝" OD | ||
Discharge | ¾" ID x 1" OD | ||
Minimum Bend Radius | 24" | ||
Maximum Pressure | 330 psig @ 70°F |
||
Maximum Continuous Length | 500' | ||
Poly: | |||
Air Supply | ⅜" ID x ½" OD | ||
Exhaust | ½" ID x ⅝" OD | ||
Discharge | ¾" ID x 1" OD | ||
Minimum Bend Radius | 24" | ||
Maximum Pressure | 120 psig @ 70°F |
||
Maximum Continuous Length | 300' |
Standard Fittings Provided:
Air – ⅜" Barb
Exhaust – ½" Barb
Discharge – ¾" Barb
Custom well caps and quick-connect fittings available upon request.
Optional Quick-Connect Fittings
Geotech can provide the compressed air equipment required for your Auto-Reclaimers.
Air CompressorsGeotech offers electric powered andgas powered compressors, selected for dependability, low maintenance and oil-free high performance. |
Air RegulatorsA variety of types for your air supply line requirements. |
Composite Housing
(L) Stainless Steel Housing (R) |
Pump Head with Top Fill |
Pump Valve |