Rental Flame Ionization Detectors (FID)

FIDs use a hydrogen flame as the means to ionize organic vapors. Once they are ionized, they can be detected and measured. FIDs respond to virtually all organic compounds, compounds that contain carbon-hydrogen or carbon-carbon bonds. FIDs will not respond to inorganic compounds. Inside the detector chamber, the sample is exposed to a hydrogen flame which ionizes the organic vapors.

FIDs are the most sensitive for saturated hydrocarbons (alkanes), unsaturated hydrocarbons (alkenes and alkynes), and aromatic hydrocarbons.

Thermo Scientific TVA2020
Toxic Vapor Analyzer

Thermo Scientific TVA2020

The Thermo Scientific™ TVA2020 Toxic Vapor Analyzer is the only intrinsically safe, portable field analyzer using both Flame Ionization Detection (FID) and Photo Ionization Detection (PID) technologies.

  • Dual FID/PID technology
  • Bluetooth enabled
  • Lightweight and compact design
  • Easy to service in the field
  • No PC based software required

Call 1.800.833.7958


Thermo Scientific TVA2020 Specifications
Thermo Scientific TVA2020 Instruction Manual

LDARtools phx42™ FID AnalyzerLDARtools phx42

The phx42™ FID technology is designed for the environmental and oil & gas industries to incorporate a safer, more efficient LDAR (Leak Detection and Repair) program. The detection of fugitive emissions and leaks with the phx42™ is immediate – leading to prompt repairs, reduced emissions, and conformity to regulatory inspections.

Call 1.800.833.7958


LDARtools phx42 Specifications
LDARtools phx42 Manual
LDARtools Cal5.0 Manual
LDARtools phx42 Basic Operation Skill Mastery Documentation
LDARtools Cal5.0 Basic Operation Skill Mastery Documentation
LDARtools phx42 Backpack Modification

Thermo Scientific TVA-1000B

Thermo Scientific TVA-1000B

The TVA-1000B is the only over the shoulder portable vapor analyzer that offers both PID (Photoionization Detection) and FID (Flame Ionization Detection). Users can measure a wide variety of organic vapors over an impressive dynamic range (0-50,000 ppm). The FID operates by breaking hydrogen-carbon bonds and is not limited by the ionization potential of the molecule.

  • Dual simultaneous FID/PID or single FID detectors
  • Portable and lightweight
  • Multiple response factors and curves
  • Multi-point calibration
  • Eight programmable location labels
  • On-board datalogging

Call 1.800.833.7958


Thermo Scientific TVA-1000B Specifications
Thermo Scientific TVA-1000B Manual