1.800.833.7958

 

sales@geotechenv.com

Español

中文

 

Geotech Interface Meter

Oil, Water & Level Meters


The Geotech Interface Meter can be used in numerous applications including measuring oil and water levels in monitoring wells, detecting tank leakage and obtaining accurate measurements of water levels. When the Geotech Interface Meter is lowered down a well and contacts the product layer, a solid tone and green light alarm is activated on the reel. When the probe detects water, the tone begins to oscillate and the light changes to red.

  • Precise oil/water layer detection
  • Highly visible printed markings in engineering or metric units
  • HDPE coated steel-core dog bone shaped tape
  • Power saving auto sleep mode
  • Buzzer and LED indicator
  • Adjustable brake resistance
  • Lightweight aluminum frame
  • Field serviceable components
  • Made in USA by Geotech Environmental Equipment, Inc.

 

Reel System Specifications    
Reel Materials:
100'-300' (30m-100m) Reel
500'-1000' (152m-305m) Reel

 
Solid Polypropylene Hub & Flange, Solid Aluminum Frame
Powder Coated Steel Hub & Flange, Aluminum Frame
Dimensions:
100'-300' (30m-100m) Reel
500'-1000' (152m-305m) Reel

 
13" H x 11" W x 7" D (33cm H x 28cm W x 18cm D)
15" H x 11" W x 9" D (38cm H x 28cm W x 22cm D)
System Weight:
(Weight of reel assembly and case)




  100 foot (30 meters) = 9 lbs. (4 kg)
200 foot (60 meters) = 11 lbs. (5 kg)
300 foot (100 meters) = 14 lbs. (6.5 kg)
500 foot (152 meters) = 20 lbs. (9.1 kg)
750 foot (229 meters) = 24 lbs. (10.9 kg)
1000 foot (305 meters) = 28 lbs. (12.7 kg)
Power:   9 Volt DC alkaline battery
Self Shut Off Time:   5 minutes
Alarm:   Audible and Visual
Warranty:   1 Year

Tape Specifications
 
Materials:   HDPE coated steel-core tape with Buna-N
Resolution:

  Imperial units 1/100 per foot
Metric units 1mm
Tape Markings:   Printed on steel-core then HDPE jacketed
Accuracy:

  1/100th of a foot per 100 feet (3mm/30.5 meters)
Per Federal Specification GGG-T-106E

Probe Specifications    
Materials:
  Glass, PTFE, 316 stainless steel, Buna-N
Weight:   4.6 oz. (130 g)
Dimensions:   5/8" OD x 6.5" L (1.59cm O.D. x 16.5cm L)
Min. Detectable Hydrocarbon Thickness:   .0312" (.8mm)
Maximum Submergence:
  100 psi (6.9 bar)

Environment Specifications    
Operating Temperature Range:
  32–140°F (0–60°C)
Storage Temperature Range:   -40–170°F (-40–75°C)
Humidity:   5-95% non-condensing

Adobe® Reader® is required

> Specifications PDF

> Installation and Operation Manual

 

 

 

 

 

 

Geotech Interface Meter with 100'-300' reel
Geotech Interface Meter with 100'-300' (30m-100m) reel
and padded carrying case.
Geotech Interface Meter with 500'-1000' reel
Geotech Interface Meter with 500'-1000' (152m-305m) reel
and padded carrying case
Field Replaceable Probe