The geosquirt Purge Pump is designed for purging shallow wells up to a maximum depth of 90 feet (27 m).
The pump is completely sealed and designed to be operated while completely submerged in water.

  • Operates to depths of 90' (27 m)
  • Very economical and reliable
  • Flow rates up to 2.5 GPM (9.5 LPM)
  • Ideal for 2" (5 cm) diameter or larger monitoring well
  • Requires an independent 12V DC power supply
  • Optional portable reel system with tubing

 

    Single Stage Double Stage Triple Stage
Dimensions
  1.43" D x 5" L
(3.6cm D x 12.7cm L)
1.68" D x 10.5" L
(4.27cm D x 26.67cm L)
1.68" D x 16" L
(4.27cm D x 41cm L)
Outlet   Requires ⅜" (10 mm)
I.D. tubing
Requires ⅜" (10 mm)
I.D. tubing
Requires ⅜" (10 mm)
I.D. tubing
Optional
Outlet Adapter
  Optional fitting allows
½" (13 mm) tubing
Optional fitting allows
½" (13 mm) tubing
Optional fitting allows
½" (13 mm) tubing
Power   Requires an independent
12V DC source
Requires an independent
12V DC source
Requires an independent
12V DC source
Current Draw   3.3 amps 6.2 amps 8.0 amps
Voltage Range   10V-15V 10V-15V 10V-15V
Principle of
Operation
  Intermittently rated
centrifugal pump
Intermittently rated
centrifugal pump
Intermittently rated
centrifugal pump
Operating
Temperature
  In water up to 140°F (60°C)
do not freeze pump
In water up to 140°F (60°C)
do not freeze pump
In water up to 140°F (60°C)
do not freeze pump
Flow Rate   Up to 2.5 GPM (9.5 LPM) Up to 2.5 GPM (9.5 LPM) Up to 2.5 GPM (9.5 LPM)
Maximum
Recommended
Depth
  30 feet (9 m) 60 feet (18 m) 90 feet (27 m)
Material of Casing   ABS plastic ABS plastic ABS plastic
Material of Seal   Rubber Rubber Rubber
Length of
Motor Lead
  30 feet (9 m) 60 feet (18 m) 90 feet (27 m)
Recommended
Duty Cycle
  5 min. off/15 min. on 5 min. off/15 min. on 5 min. off/15 min. on

 

The geosquirt purge pump can be purchased alone or as a complete system with reel and tubing. It is used to pump large quantities from shallow wells. Pump should be allowed to cool for 5 minutes for every 15 minutes of operation. It can operate in water temperatures as high as 140°F (60°C), but must be submerged at all times.

 

Geosquirt Flow Curves

 

Adobe® Reader® is required

> Specifications PDF

> Installation and Operation Manual

 

 

 

 

 

 

Single Stage geosquirt
Single Stage geosquirt with 30 ft. (9 m) Motor Lead
Double Stage geosquirt
Double Stage geosquirt with 60 ft. (18 m) Motor Lead
Triple Stage geosquirt
Triple Stage geosquirt with 90 ft. (27 m) Motor Lead