Automatic Peristaltic Sampling Pump


The Geotech Auto Sampler automatically collects numerous individual discrete samples taken at regular intervals over a period of time. The flow-weighted sample collected is representative of an average concentration of any substance being analyzed. Designed for portable or dedicated applications, the Geotech Auto Sampler is effective in outfall, in-stream, manhole, and open-fluid sample point applications.


  • Community/targeted SARS-CoV-2 (COVID-19) early detection

  • Wastewater effluent

  • Industrial pre-treatment

  • Permit compliance

  • 24 hour composite sampling


  • Round 15.8" (40cm) diam. Enclosure

  • Auto Sampler Pump and Controller

  • easy-load II® Pump Head

  • Sample Bottle Float Switch

  • Rechargeable Batteries x 2 and Charger x 1

  • Pump Tube x 5'

  • Suction Tube x 100'

  • 2.6 Gallon LDPE Sample Bottles x 2

  • Stainless Steel Suction Intake

  • DC Power Cord, with AMP & Clips


  • Suspension harness

  • AC Power Converter

System    
Size (Diam. x Ht.):
  15.81 x 23.25 inches (40 x 59 cm)
Weight:   Dry Weight – 24 lbs. (12 kg)
Wet Weight – 49 lbs. (22 kg)
Sample Bottle:   2.6 Gallon HDPE Bottle
Sample Cooling:   Reusable Ice Packs (not included)
Pump Tubing:   .25" (6.4mm) ID Standard
.375" (9.5mm) ID Max Flow
Suction Tubing:   .25" x .375" (6 x 10mm) Standard
.375" x .5" (10 x 13mm) Max Flow
Intake Strainer:   .85" OD Stainless Steel Intake
Pump & Controller    
Power Requirements:   12 VDC²
Principle of Pump Operation:   Peristaltic Pump
Fluid Delivery Rate:   1800 ml/min Standard – 3400 ml/min Max Flow
Maximum Lift:   29 ft. (8.8 m) Standard at sea level⁴
27 ft. (8.3 m) Max Flow at sea level⁴
Onboard Battery:   9 Ah Lead-Acid³
Battery Life:   1 hour continuous operation
Sample Mode:   Linear
Intake Purge:   Auto backflush cycle
Start Delay:   0-12 hours⁵
Sample Time:   0-15 minutes⁵ (0-30 seconds and 1 min. – Full)
Sample Interval:   0-12 hours⁵ (0-60 minutes and 2-12 hours)
Sample Size:   50 ml – 10+ liters
Overflow Protection:   Shut-Off input float switch
System Status:   LED indicator
Operational Temp:   32°-120°F (10°- 49°C)

² 12V DC input power required. Optional AC converter allows for continuous operation with reliable 115V AC power source.
³ System kit includes two batteries. System requires only one battery for operation. Geotech recommends swapping
   batteries each time sample bottle is replaced.

Ft. elevation x 0.0005 x 2.31 – Suction lift H2O ft. at sea level = ft. actual H2O suction lift.
Start delay, sample time, and sample intervals can be programed for custom interval(s) at time of order.